AT commands
RO (Packetization Timeout)
Set or read the number of character times of inter-character silence required before transmission
begins when operating in Transparent mode. Only use RO when the device is operating in Transparent
mode (AP = 0).
Set RO to 0 to transmit characters as they arrive instead of buffering them into one RF packet.
The RO command only applies to Transparent mode, it does not apply to API mode.
Parameter range
0 - 0xFF (x character times)
Default
3
D6 (DIO6/RTS)
Sets or displays the DIO6/RTS configuration (Micro pin 27/SMT pin 29/TH pin 16).
Parameter range
0, 1, 3 - 5
Parameter
0
1
3
4
5
Default
0
D7 (DIO7/CTS)
Sets or displays the DIO7/CTS configuration (Micro pin 24/SMT pin 25/TH pin 12).
Parameter range
0, 1, 3 - 7
Parameter
0
1
3
Digi XBee® 3 Zigbee® RF Module
Description
Disabled
RTS flow control
Digital input
Digital output, low
Digital output, high
Description
Disabled
CTS flow control
Digital input
Serial interfacing commands
203