Network Discovery Options); Np (Maximum Packet Payload Bytes); Zigbee Addressing Commands; To (Transmit Options) - Digi XBee 3 ZigBee User Manual

Rf module
Table of Contents

Advertisement

AT commands
Parameter range
0x20 - 0xFF (x 100 ms)
Default
0x3C (6 seconds)
NO (Network Discovery Options)
A bitfield that contains advanced network discovery options that do not have dedicated AT commands.
These options only affect the behavior of the local device when you issue an ND command or when
sending a node identification.
Parameter range
0 - 3
Option Description
Append the DD (Digi Device Identifier) value to ND responses and node identification
0
frames.
Local device sends ND response when the ND is issued.
1
Default
0x0

NP (Maximum Packet Payload Bytes)

Reads the maximum number of RF payload bytes that you can send in a transmission based on
current parameter settings.
Using APS encryption (API transmit option bit enabled), reduces the maximum payload size by 9 bytes.
Using source routing (AR < 0xFF), further reduces the maximum payload size depending on how many
hops are traversed.
Note
NP returns a hexadecimal value. For example, if NP returns 0x54, this is equivalent to 84 bytes.
Parameter range
[read-only]
Default
N/A

Zigbee addressing commands

The following AT commands adjust the advanced communication settings that affect outgoing data
transmissions.

TO (Transmit Options)

The bitfield that configures the advanced options used for outgoing data transmissions for a device
operating in transparent mode (AP=0).
Digi XBee® 3 Zigbee® RF Module
Zigbee addressing commands
194

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XBee 3 ZigBee and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents