AT commands
Parameter range
Standard baud rates: 0x0 - 0x0A
Non-standard baud rates: 0x12C - 0x0EC400
Parameter
0x0
0x1
0x2
0x3
0x4
0x5
0x6
0x7
0x8
0x9
0xA
Default
0x03 (9600 baud)

NB (Parity)

Set or read the serial parity settings for UART communications.
Parameter range
0 - 2
Parameter
0
1
2
Default
0

SB (Stop Bits)

Sets or displays the number of stop bits for UART communications.
Parameter range
0 - 1
Digi XBee® 3 Zigbee® RF Module
Description
No parity
Even parity
Odd parity
Serial interfacing commands
Description
1200 baud
2400 baud
4800 baud
9600 baud
19200 baud
38400 baud
57600 baud
115200 baud
230,400 baud
460,800 baud
921,600 baud