Digi XBee 3 ZigBee User Manual page 338

Rf module
Table of Contents

Advertisement

Over-the-air firmware/file system upgrade process for Zigbee 3.0
Command
ZCL OTA
ID
command
0x02
Query Next
Image
Response
0x0B
Default
Response
0x05
Image Block
Response
0x08
Upgrade End
Response
The status field in the Upgrade End Status has more extensive error defines than in Zigbee, which are:
ZCL OTA command
0x06
Upgrade End Request
Digi XBee® 3 Zigbee® RF Module
Status XCTU message
0x80
Incorrect Query Next Image Response Format
0x85
Attempting to upgrade to invalid firmware
0x89
Image size is too big
0x8A
Please ensure that the image you are attempting to
upgrade has a different version than the current version
0x01
ZCL OTA Message Out of Sequence
0x80
Incorrect Image Block Response Format
0x01
ZCL OTA Message Out of Sequence
0x--
Mismatched Offset
0x87
Upgrade File Mismatch
0X87
Wrong Upgrade File
Status
Error message
0x94
Client Timed Out
0x96
Invalid OTA Image
0x95
Client Aborted Upgrade
0x05
Storage Erase Failed
0x87
Contact Tech Support (Highly unlikely to occur)
ZCL OTA cluster status codes
338