Frame descriptions

Remote AT Command Request frame - 0x17

Description
Used to query or set device parameters on a remote device. For parameter changes on the remote
device to take effect, you must apply changes, either by setting the Apply Changes options bit, or by
sending an AC command to the remote.
Format
The following table provides the contents of the frame. For details on frame structure, see
format.
Frame
data
fields
Offset Description
Frame
3
type
Frame ID
4
64-bit
5-12
destination
address
Reserved
13-14
Digi XBee® 3 Zigbee® RF Module
0x17
Identifies the data frame for the host to correlate with a subsequent
response.
If set to 0, the device does not send a response.
MSB first, LSB last. Set to the 64-bit address of the destination device.
Reserved 64-bit address for the coordinator = 0x0000000000000000
Broadcast = 0x000000000000FFFF.
Reserved broadcast address: 0x000000000000FFFF
Note
Digi highly discourages sending remote AT commands to a broadcast.
You will only receive a single acknowledgment despite there being multiple
recipients, and there is no assurance that the broadcast will be successfully
received by the rest of the network.
MSB first, LSB last. Set to match the 16-bit network address of the destination
device, if known. Set to 0xFFFE if the address is unknown, or if sending a
broadcast.
Remote AT Command Request frame - 0x17