AT commands
Addressing commands
The following AT commands are addressing commands.
CI (Cluster ID)
Sets or reads the default cluster identifier value that the device uses for serial data transmissions.
If you set this value to 0x12 (loopback Cluster ID), the destination node echoes any transmitted packet
back to the source device.
Parameter range
0 - 0xFFFF
Default
0x11 (Transparent data cluster ID)
DH (Destination Address High)
Set or read the upper 32 bits of the 64-bit destination address. When you combine DH with DL, it defines
the destination address that the device uses for transmissions in Transparent mode.
0x000000000000FFFF is the broadcast address.
Parameter range
0 - 0xFFFFFFFF
Default
0
XTend vB DigiMesh RF Module User Guide
34