Parameter Switch
Toggles between custom defaults and power on settings, as if
received, respectively. Note that the button must be configured for "parameter switch"
in both custom and power on settings in order to be able to toggle between the two.
Default on Power-on
Definition:
When enabled, if the EZ Button is held down during power-on, the reader
will default to customer defaults and save for power-on. This is the same
as sending a
Serial Cmd:
<K770,global
Default:
Enabled
Options:
0 = Disabled
EZ Button Auto Framing
Definition:
Configures the reader's Auto Framing process as initiated from the EZ
Button. Raster framing is performed first, followed by laser framing, as
enabled. During the raster framing process, the scan line used depends
on the "laser status".
Raster Status
Definition:
When enabled, Raster Framing will be performed whenever a framing
process is ordered.
Serial Cmd:
<K773,raster
Default:
Disabled
Options:
0 = Disabled
Laser Status
Definition:
When enabled, Laser Framing will be performed whenever a framing
process is ordered.
Serial Cmd:
<K773,raster
Default:
Enabled
Options:
0 = Disabled
MS-860 Industrial Raster Reader User's Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
<Zrc>
command.
status,default on
power-on>
1 = Enabled
status,laser status>
1 = Enabled
status,laser
status>
1 = Enabled