Ordered Output
Data
Definition:
User-assigned data that the reader will search for.
Serial Cmd:
<K744,filter index,symbology type,length,wildcard character,placeholder
character,data,decode direction,check database number>
Default:
Null
Options:
Any pairing of hex digits representing ASCII characters;
e.g., 41422A = "AB*"
(00 = disabled)
Decode Direction
Definition:
The current symbol decode direction is compared with the direction of the
filter. If decode direction comparison succeeded then move to the next
item.
Serial Cmd:
<K744,filter index,symbology type,length,wildcard character,placeholder
character,data,decode
Default:
Any Direction
Options:
0 = Any direction
Check Index
Definition:
The configuration database of the first decode of a symbol is compared
with the filter indexes, as enabled. If a match occurs, the current symbol
is a qualified symbol and will be saved for output. If it does not match,
the remaining filters are searched again, starting again with symbology
type.
Serial Cmd:
<K744,filter index,symbology type,length,wildcard character,placeholder
character,data,decode
Default:
0
(0 = any database)
Options:
0 = Any Index
13-14
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
direction,check database number>
1 = Forward
direction,check database
1 = Database #1...12