Microscan MS-860 User Manual page 138

Table of Contents

Advertisement

Minimum Bars
Definition:
Specifies the direction that a bar can be read.
Serial Cmd:
<K477,status,fixed bar length status,fixed bar
bars,bar widths,direction,fixed threshold value>
Default:
4
Options:
4 to 16
Bar Width Status
Serial Cmd:
<K477,status,fixed bar length status,fixed bar length,min. no. of bars,
bar
widths,direction,fixed threshold value>
Default:
Mixed
Options:
0 = Mixed
1 = Narrow
Direction
Definition:
Specifies the direction that a bar can be read.
Serial Cmd:
<K477,status,fixed bar length status,fixed bar length,min. no. of bars,
bar widths,direction,fixed threshold value>
Default:
Forward
Options:
0 = Forward
Fixed Threshold Value
Definition:
Used when Bar Width Status field is set to Fixed Threshold Value.
Serial Cmd:
<K477,status,fixed bar length status,fixed bar length,min. no. of bars,
bar
widths,direction,fixed threshold
Default:
400
Options:
1 to 65535
MS-860 Industrial Raster Reader User's Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
length,min. no. of
2 = Wide
3 = Fixed Threshold Value
1 = Reverse
value>
Symbologies