Postamble
Postamble
Postamble Status
Usage:
Used for identifying and controlling incoming data. For example, defining
the postamble as a carriage return and a line feed causes each decoded
message to be displayed on its own line.
Definition:
Defines a one to four character data string that can be added to the end
of the decoded data.
Serial Cmd:
<K142,status,postamble character(s)>
Default:
Enabled
Options:
0 = Disabled
Postamble Character(s)
Serial Cmd:
<K142,status,postamble
Default:
CR LF
(^M^J) Corresponds to carriage return/line feed/null/null, as dis-
played in the menu.
Options:
Up to four user-defined ASCII characters, including control characters.
Within a Serial Command
To enter control characters within a serial command, hold down the con-
trol key while typing the desired character.
Example:
Within an Embedded Menu
Control characters entered on the command line are displayed in the
menu as mnemonic characters, such as:
To enter a control character from within an embedded menu, first type in
a space (with the space key). This has the effect of allowing the control
key to be recognized as a part of the control character. Next hold down
the control key while typing the desired character.
Example:
6-20
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
1 = Enabled (within any protocol)
character(s)>
<K142,1,CTRL-m CTRL-j>
Space CTRL-m Space CTRL-j
to enter ^M^J.
<CR><LF><NUL><NUL>
to enter ^M^J.