Large Intercharacter Gap
Usage:
It is helpful for reading symbols that are printed out of specification.
Caution: Do not use Large Intercharacter Gap with Narrow Margins
enabled since enabling Large Intercharacter Gap (over 3x) could
cause a narrow margins (5x) to be interpreted as an intercharacter gap.
Definition:
Instructs the reader to read symbols with gaps between characters
exceeding three times the narrow element width.
Serial Cmd:
<K471,status,start & stop match status,start & stop output
intercharacter
digit type,check digit output status>
Default:
Disabled
Options:
0 = Disabled
Fixed Symbol Length Status
Usage:
Helps prevent truncations and increases data integrity by ensuring that
only one symbol length will be accepted.
Definition:
When set to Enabled, the reader will check the symbol length against the
Fixed Symbol Length field.
Serial Cmd:
<K471,status,start & stop match status,start & stop output status,large
intercharacter
digit type,check digit output status>
Default:
Disabled
Options:
0 = Disabled
Symbol Length
Definition:
Specifies the exact number of characters that the reader will recognize
(this does not include start and stop and check digit characters). The
reader ignores any symbol not having the specified length.
Serial Cmd:
<K471,status,start & stop match status,start & stop output status,large
intercharacter gap,fixed symbol length
type,check digit output status>
Default:
10
Options:
1 to 128
MS-860 Industrial Raster Reader User's Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
gap,fixed symbol length status,symbol length,check
1 = Enabled
gap,fixed symbol length
1 = Enabled
status,symbol
Symbologies
status,large
status,symbol length,check
length,check digit
9-15
Need help?
Do you have a question about the MS-860 and is the answer not in the manual?