1D Symbologies
Application Record Padding
Definition:
Padding is the insertion of zeros to make up the maximum length of a
variable application record data field, except for the last field which does
not require padding.
When enabled, padding is included. When disabled, padding is omitted.
Note: Padding is never added to fixed length fields or to the last data
field of a symbol. Enabling or disabling Record Padding will have no
effect on these.
Serial Cmd:
<K474,status,fixed symbol length status,fixed symbol length,EAN-128
status,output format,application record separator status,application
record separator character,application record
record
padding>
Default:
Enabled
Options:
0 = Disabled
Note: Output Format must be set to Application Record before this parameter can
take effect.
9-10
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
brackets,application
1 = Enabled