EZ Button
Calibration: The calibration routine will be initiated (see
"Calibration Options"
on
page 4-6). To abort calibration, tap the EZ Button once quickly.
Save for Power-on: When when this button position is selected, all reader settings
will be saved to non-volatile memory to be recalled when reader is powered-on the next
time. This is the same as sending the
<Z>
in the terminal.
Auto Frame: Auto Framing will be initiated when this button position is selected. To
abort auto-framing, press the EZ Button once quickly. Auto framing is a background
routine that automatically adjusts the scan width to the length of a symbol. This proce-
dure can also be accessed in a terminal view by the
<@>
command. (See
"EZ Button
Auto Framing"
on page 3-7 for options).
Load New Master: This allows the button to function the same as the New Master Pin
command. The new master pin's consecutive decode requirement holds true for this but-
ton position when this mode is selected. (See
"Sequence Step"
on page 11-11.)
Sleep Mode: If sleep mode is enabled, the EZ Button will shut off the mirror motor and
laser. To exit sleep mode, tap the EZ Button once quickly.
Label Configuration: Enables label configuration mode when this button position is
selected. To disable, simply tap the Configuration Button once quickly. In normal read-
ing modes, it is required to read a special Code 128 label with a special codeword used
by AIM to signify reader programming. When entering label configuration by the EZ
Button, the special Code 128 label is not required.