Guard Bar
Usage:
Useful when I–2/5 multisymbols are enabled to prevent false data out-
put. This typically occurs with highly tilted or skewed symbols.
Definition:
A guard bar is a heavy bar, at least 2 times the width of the wide bar, sur-
rounding the printed I–2/5 symbol and helping to prevent false reads.
Serial Cmd:
<K472,status,check digit status,check digit output status,symbol length
#1,symbol length
Default:
Disabled
Options:
0 = Disabled
Range Mode Status
Usage:
Useful in applications where symbol lengths may vary.
Definition:
Allows user the option to define a minimum and maximum symbol length
range for I–2/5.
Serial Cmd:
<K472,status,check digit status,check digit output status,symbol length
#1,symbol length #2,guard bar
Default:
Disabled
Options:
0 = Disabled
When enabled, the symbol length range is defined by the values set in Symbol Length
#1 and Symbol Length #2.
For example, if the symbol lengths are defined as 10 and 6, a symbol of length 6, 8, or
10 will qualify as candidates for I–2/5.
Note: Either length (1 or 2) can qualify as the minimum or maximum.
MS-860 Industrial Raster Reader User's Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
#2,guard bar
status,range mode>
1 = Enabled
status,range
1 = Enabled
Symbologies
mode>
9-13