Response Timeout - Microscan MS-860 User Manual

Table of Contents

Advertisement

Response Timeout

Response Timeout

Usage:
Used only when a response is required from the host. While in Multi-
drop, if the reader does not receive an ACK or NAK from the host after
sending polled data, it will act on a fault. The reader can be set to wait
indefinitely by setting Response Timeout to zero.
Definition:
Time the reader will wait before timing out if ACK, NAK, and ETX are
enabled, and a host response is expected.
Serial Cmd:
<K143,response
Default:
2
(x 10 = 20 mS)
Options:
0 to 255 in 10mS increments (0 to 2.55 seconds)
(A zero (0) setting causes an indefinite wait.)
6-22
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com