6.3 Adjusting the Media Sensors

You can check the media sensor condition and adjust the media sensor level for optimum performance.
6.3.1
Adjusting the Media Sensor Automatically
The automatic adjustment procedure for the media sensor is as follows:
1
When the product is in online mode,
press the
LINE button to change the
product to offline mode.
2
Press the
ENTER button.
The product changes to the setting mode menu.
3
Select the SERVICE MODE using the
buttons and then press the
/
/
/
ENTER button.
SERVICE MODE setting screen shows.
Note
If password function is enabled, PASSWORD is shown
on the screen instead. Enter the password to continue.
4
Select the SENSOR LEVEL using the
buttons and then press the
/
ENTER button.
SENSOR LEVEL shows on the screen.
5
Select AUTO using the
then press the
SENSOR SELECT shows on the screen.
buttons and
/
ENTER button.
6 Adjusting the Product