8 Troubleshooting
Error
No.
Message
Parity error
03
Overrun error
04
Framing error
05
Buffer overflow
06
300
S84-ex/S86-ex Operator Manual
LED/Buzzer
Flashes blue and red
RS-232C settings are
alternately.
incorrect.
The cable connection is
Three short beeps.
incorrect.
To clear the error:
Power off the
product.
Flashes blue and red
RS-232C settings are
alternately.
incorrect.
The cable connection is
Three short beeps.
incorrect.
To clear the error:
Power off the
product.
Flashes blue and red
RS-232C settings are
alternately.
incorrect.
The cable connection is
Three short beeps.
incorrect.
To clear the error:
Power off the
product.
Flashes blue and red
The size of the received
alternately.
data exceeds the size of
the receive buffer.
Three short beeps.
The communication
settings between the
To clear the error:
product and the host are
Power off the
incorrect.
product.
Cause
Countermeasure
Adjust the interface
settings correctly.
Check and connect the
cable correctly.
Adjust the interface
settings correctly.
Check and connect the
cable correctly.
Adjust the interface
settings correctly.
Check and connect the
cable correctly.
Do not send data that
exceeds the size of the
receive buffer.
Set the communication
between the product and
the host correctly.