SENSOR LEVEL I-MARK SLICE
Shows the current level (Reception) of the I-mark sensor on the upper part
of the screen.
The slice level is calculated automatically and shown on the bottom line.
The slice level can be set to 0.0 V, or from 0.3 V to 2.9 V. (adjustable in
increments of 0.1 V)
Note
• The slice level is set automatically when the value is set to 0.0 V.
• In the case of automatic calculation, the calculated value will be shown
automatically after printing.
SENSOR LEVEL GAP(E)
Shows the current level (Emission) of the gap sensor on the upper part of
the screen.
This offset determines how soon the sensor will respond to an incoming
gap. The adjustment range is from 1 to 3 and is shown on the bottom line
of the screen.
SENSOR LEVEL GAP(R)
Shows the current level (Reception) of the gap sensor on the upper part of
the screen.
This offset determines how soon the sensor will respond to an incoming
gap. The adjustment range is from 0 to 127 and is shown on the bottom
line of the screen.
SENSOR LEVEL GAP SLICE
Shows the current level (Reception) of the gap sensor on the upper part of
the screen.
The slice level is calculated automatically and shown on the bottom line.
The slice level can be set to 0.0 V, or from 0.3 V to 2.9 V. (adjustable in
increments of 0.1 V)
Note
• The slice level is set automatically by the firmware when the value is set
to 0.0 V.
• In the case of automatic calculation, the calculated value will be shown
automatically after printing.
4 Operation and Configuration
S84-ex/S86-ex Operator Manual
131