Error
No.
Message
Overheat error
26
Command error
27
CRC check error
35
35
35
Wireless LAN error
37
37
37
LED/Buzzer
Flashes blue and red
The temperature of the
alternately.
product has exceeded its
tolerance value.
One long beep.
To clear the error:
Stop the operation of
the product and wait
until the temperature
decreases.
Flashes red.
Incorrect command or
parameter in the print
Three short beeps.
data.
To clear the error:
Caaa: position of error
occurrence
Press the
LINE
button.
<bb>: error command
name
cc: error code
Flashes red.
The CRC code of the data
to be sent (one item) is
Three short beeps.
incorrect.
To clear the error:
Press the
LINE
button or cancel the
print job.
Flashes blue and red
No wireless LAN unit is
alternately.
connected while the
product is in wireless LAN
Three short beeps.
download mode.
The product failed to
To clear the error:
connect to the wireless
Power off the
LAN unit.
product.
Cause
Countermeasure
Stop the operation of the
product to let the
temperature decrease.
Check the print data.
Refer to
More Information about
Command Error
details.
Check the data to be sent
and the interface settings.
LINE button: Continue
printing from the print data
where the CRC error
occurred.
Send the SUB command:
Clear the CRC error and
continue printing from
where it stopped.
Make sure that the
wireless LAN unit is
connected correctly.
Change the wireless LAN
unit.
*When you change the
wireless LAN, the data
port and sub port in the
communication settings
change depending on the
settings.