6 Adjusting the Product
6.3.2

Adjusting the I-mark Sensor Level Manually

The adjustment procedure for the I-mark sensor level is as follows:
1
Go to the SENSOR LEVEL setting screen
of SERVICE MODE.
Perform steps 1 through 4 of
Adjusting the Media Sensor
2
Select MANUAL using the
and then press the
The light emission level adjustment of the I-mark
sensor is shown.
3
On the SENSOR LEVEL I-MARK(E)
screen, press the
ADJUST LEVEL to 2 and then press the
ENTER button.
The adjustment range of ADJUST LEVEL is from 0
to 3.
We recommend using the initial value, which is 2.
The light reception level adjustment of the I-mark
sensor is shown.
First, adjust the "Low" reception level (voltage) of the I-mark sensor.
4
Open the top cover and unlock the media
feed and media sensor assembly .
5
Physically place the media , with the
portion without the I-mark resting over the
I-mark sensor.
6
Press the media feed and media sensor
assembly  down to lock it.
To get the correct adjustment result, close the
media sensor assembly before performing the
adjustment.
272
S84-ex/S86-ex Operator Manual
Section 6.3.1
Automatically.
buttons
/
ENTER button.
buttons to set
/
1
2
I-mark sensor

Advertisement