Adjusting The Paper End Sensor - SATO S84-ex Operator's Manual

Hide thumbs Also See for S84-ex:
Table of Contents

Advertisement

6.3.4

Adjusting the Paper End Sensor

This adjustment procedure is used when I-mark is selected as the paper end sensor.
When Gap sensor is selected as the paper end sensor, adjust the Gap sensor level as in
Adjusting the Gap Sensor Level
The checking and adjustment procedures for the paper end (I-mark) sensor level are as follows:
1
Go to the SENSOR LEVEL I-MARK(R)
setting screen of SERVICE MODE.
First, check the I-MARK(R) value (voltage) of the paper end (I-mark) sensor when the
liner is placed on the sensor.
2
Open the top cover and unlock the media
feed and media sensor assembly .
3
Physically place the liner  without the
label resting over the I-mark sensor.
4
Press the media feed and media sensor
assembly  down to lock it.
To get the correct adjustment result, close the
media sensor assembly before performing the
adjustment.
5
Check if the I-MARK(R) value is 2.0 V or
lower.
If not, change ADJUST LEVEL using the
buttons until the I-MARK(R) value is 2.0 V or lower.
Manually.
1
2
/
6 Adjusting the Product
Section 6.3.3
I-mark sensor
I-MARK(R) level: ≤ +2.0V
S84-ex/S86-ex Operator Manual
277

Advertisement

Table of Contents
loading

This manual is also suitable for:

S86-ex