J ASSEMBLY
Procedure for the E89-M3 Sensor I/O Connector Cable
(Sold Separately) and
XS8A-0442 Cable Connector
(Provided with Sensor)
1. Processing the Cable End
The cable end is semi-stripped.
Semi-stripped
Cut the end as shown in the following illustration.
20 mm min.
2. Fitting Controller Conductors to Cable Connector Cover
Terminal numbers are engraved on the cover. Refer to the
following and be sure that these terminal numbers
correspond to the wire colors correctly.
Terminal No.
I/O cable
1
Black (Output)
2
Pink (LED lighting input)
3
Brown (Vcc)
4
Blue (GND)
Note: When connecting the cable to the E8CB-01C for 0 to 98
kPa use, do not connect the white wire to any pin. Cut the
white wire and apply insulation tape so that the white wire
will not touch any other wire or pin directly.
Cut
White cable
Connector
Terminal no.
I/O cable
1
Black (Output)
2
---
3
Brown (Vcc)
4
Blue (GND)
Check again that the terminal numbers correspond to the wire
colors correctly. Then, insert the cover into the plug connector.
Terminal number
Plug connector
Cover
28
Be sure that the cover is fully inserted into the plug connector.
3. Connecting Wires to Plug Connector
Temporarily place the wired cover on the plug connector.
Press the cover and fit the wires. If using pliers, apply the
pliers to the middle part of the cover and press the cover as
straight as possible against the plug connector.
Be sure that there is no space between the cover and plug
connector.
Check through the cover window that the wires are fitted to
the plug connector correctly.
Once attached to the plug connector, the cover and plug
connector cannot be reused. Before using the pliers to attach
the cover, be sure that the terminal numbers correspond to
the wire colors correctly. If the wires are connected to the
plug connector incorrectly, use a new cable connector.
4. Connecting/Disconnecting Controller Connector to/from the
K3C-MP8-T1Z Four-channel Pressure Controller
Be sure that terminal number 1 engraved on the cable
connector is facing up (i.e., on the lock-lever side) and press
the cable connector against the socket connector until the
cable connector snaps in place.
Lift up the lock lever before disconnecting the plug connector.
(1)
(2)