Instruction Sheet; Installation - Omron E3X-HD11 Instruction Sheet

Smart fiber sensor
Hide thumbs Also See for E3X-HD11:

Advertisement

Smart Fiber Sensor
E3X-HD
Series

INSTRUCTION SHEET

Thank you for selecting an OMRON product. This sheet
primarily describes precautions
required in installing and operating the product.
• A specialist who has the knowledge of electricity must treat
the product.
• Please read this manual carefully, and use it correctly after
thoroughly understanding the product.
• Please keep this manual properly for future reference
whenever it is necessary.
©
OMRON Corporation 2011 All Rights Reserved.
* 2 1 9 2 1 8 5 - 2 B *
PRECAUTIONS ON SAFETY
Meanings of Signal Words
Indicates a potentially hazardous situation which, if not avoided,
CAUTION
may result in minor or moderate injury or in property damage.
Warning Indications
PRECAUTIONS
Do not use the product with voltage in excess of the rated voltage.
Excess voltage may result in malfunction or fire.
Never use the product with an AC power supply. Otherwise,
explosion may result.
PRECAUTIONS FOR SAFE USE
The following precautions must be observed to ensure safe operation of the Sensor.
• Do not use the Sensor in environments subject to flammable or explosive gases.
• Do not use the Sensor in environments subject to exposure to water, oil, chemicals, etc.
• Do not install the Sensor in environments subject to intense electric field or ferromagnetic field.
• Do not attempt to disassemble, repair, or modify the Sensor Unit in any way.
• Do not apply voltages or currents that exceed the rated ranges.
• Do not use the Sensor in any atmosphere or environment that exceeds the ratings.
• Do not miswire such as the polarity of the power supply.
• Connect the load correctly.
• Do not short both ends of the load.
• Do not use the Sensor if the case is damaged.
• When disposing of the Sensor,treat it as industrial waste.
• Burn injury may occur. The Sensor surface temperature rises depending on application conditions, such as the
ambient temperature and the power supply voltage. Use caution when operating or cleaning the Sensor.
• High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing
them in the same duct may cause induction, resulting in malfunction or damage.
• When setting the Sensor, be sure to check safety such as by stopping the equipment.
PRECAUTIONS FOR CORRECT USE
• Do not install the Sensor in the following locations.
(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas
(4) Locations subject to vibration or mechanical shocks exceeding the rated values
• Use an extension cable with a minimum thickness of 0.3 mm
2
and less than 100 m long.
• Do not apply the forces on the cord exceeding the following limits:
Pull: 40N; torque: 0.1N·m; pressure: 20N; bending: 3 kg
• The Sensor is ready to operate 200 ms after the power supply is turned ON. If the Sensor and load are
connected to power supplies separately, turn ON the power supply to the Sensor first.
• When using a Wire-saving connector type product, place a protective label (provided with the E3X-CN
series connectors) on the power supply connecting terminals that are not used, to prevent electric shock
or short circuit.
Protective Label
Power Supply Connecting Terminal
• Output pulses may occur when the power supply is turned OFF. Turn OFF the power supply to the load
or load line first.
• Excessive incident light cannot be sufficiently handled by the mutual interference prevention function
and may cause malfunction. To prevent this, set a higher threshold level.
• Make sure that the power supply is turned OFF before connecting, separating or adding Amplifier Units.
• Do not pull or apply excessive pressure or force (exceeding 9.8N) on the Fiber Unit when it is mounted
on the Amplifier Unit.
• The E3X-MC11-SV2 and E3X-MC11-S Mobile Consoles cannot be used.
• Mutual interference prevention does not function among the E3X-DA-N/SD/NA amplifiers. It functions
among E3X-DA-S/MDA models.
• The E3X-DRT21-S, E3X-CRT and E3X-ECT Communication Units cannot be used.
• Always keep the protective cover in place when using the Amplifier Unit.
• Dor not use thinner, benzine, acetone, and lamp oil for cleaning.
Checking the Package Content
• Amplifier Unit: 1
• Instruction Sheet (this sheet): 1 (Japanese, English and Chinese)
1

Installation

1-1
Dimensions
21.7
27.1
Brown: 12 to 24 VDC
Black: Output
Blue: 0 V
146.9 (Max. with the protective cover open)
5.1
9
2-2.4 dia.
20.5
<Wire-saving Connector Model>
37.9
20.5
With an thin-diameter ber
attachment (E39-F9)
71.8
<Pre-wired Model>
Dimensions in parentheses () indicates the ones with related components.
1-2
Mounting the Ampli er Unit
■ Mounting on DIN Track
1.
Let the hook on the Amplifier Unit's Fiber Unit
connection side catch the track and push the
unit until it clicks.
■ Removing from DIN Track
1.
Fiber Unit Connection Side Hook
Push the unit in the direction 1.
2.
Lift it up in the direction 2.
2
Refer to "1-1. Dimensions" or check the side of
the unit for wire color and role indications.
■ Mounting Ampli er Units in Group
(Wire-saving Connector Type Models)
1.
Mount the Amplifier Units one at a time onto the
DIN track and push them until they click.
Use E3X-CN11 (Master connector) for the master
Amplifier Unit and E3X-CN12 (Slave connector) for
the slave Amplifier Units.
2.
Slide the Ampli er Units in the direction 2.
3.
Use End Plates (PFP-M: separately sold) at the both
ends of the grouped Amplifier Units to prevent them
from separating due to vibration or other cause.
4.
Tighten the screw on the End Plates using a driver.
Up to 16 Amplifier Units can be mounted in a group.
Under environments such as vibration, use an end plate
even with a single amplifier unit.
Tighten the screw while pressing the End Plate.
1-3
Mounting Fiber Unit
■ Use Fiber Cutter
2
1.
Insert a Fiber Unit into a fiber cutter hole.
Insert a standard Fiber Unit up to the
position in which it is cut; and
a thin-diameter Fiber Unit to the
bottom of the hole.
Standard Fiber Unit
2.
1
Press down the blade at a single
Hole (dia. 2.2 mm) x 3
stroke to cut the Fiber Unit.
■ Mount Fiber Unit
Lock Lever
1.
Lock
Open the protective cover.
Release
4
2.
Raise the lock lever.
2
3.
Insert the Fiber Unit in the fiber
unit hole to the bottom.
3
4.
Return the lock lever to the original
position and fix the Fiber Unit.
Fiber Unit
When mounting a coaxial reflective
Fiber Unit, insert the single-core
Fiber Unit to the upper hole (Emitter
side) and the multi-core Fiber Unit to
the lower hole (Receiver side).
Single Core
Multi Core
-1-
2
Settings
2-1
Setting and Display Overview
Unit: mm
[L/D Indicator]
[DPC Indicator]
Displays
Turns ON when Dynamic Power Control is
effective.
Light ON/Dark O setting.
[OUT Indicator]
[ST Indicator]
Turns ON when Smart Tuning is in progress.
Turns ON when Output is
ON.
Threshold Level
Incident Light
Green Digital Display
Level
Red Digital Display
Sensitivity Setting
Minute Threshold
Adjustment
[    ] Button
[UP/DOWN] Button
A single press each for setting
with/without a workpiece.
The green digital value changes.
[ST Indicator] turns ON.
2
4
1
3
2-2
Switching Control Output
11.2
<M8 Connector Model>
1.
Press     button.
L/D
Through-beam: Set to "Dark ON" to turn the
output ON with a workpiece in the detection area.
[L/D Indicator] turns   ON.
Re ective: Set to "Light ON" to turn the
output ON with a workpiece in the detection area.
[L/D Indicator] turns
ON.
1
2-3
Smart Tuning [Easy Sensitivity Setting]
Detect for Workpiece Presence/Absence
DIN Track
2-point Tuning
1.
2
Press
button with a workpiece in the detection area.
2.
Press
button again without a workpiece in the detection area.
4
3
Incident light level setting: The larger incident level of the Step 1 and 2 values is
adjusted to the power tuning level.
Threshold setting: Set to the middle between the Step 1 and 2 incident light levels.
Fiber Cutter E39-F4
Step 1 and Step 2 can be reversed.
(Provided with
the Fiber Unit)
Detect for Workpiece Presence/Absence
Thin-diameter
Fiber Unit Hole x 2
Maximum Sensitivity Tuning
Thin-diameter Fiber
1.
Attachment: E39-F9
Hold
button for 3 seconds or longer with/without workpiece as shown below.
Release the button when [
] is displayed.
Through-beam: Workpiece is present
Protective Cover
1
Workpiece
Re ective: Workpiece is absent
The red digital display changes
Incident light level setting: The incident level in Step 1 is adjusted to "0".
Threshold setting: The value is set to approx. 7% of the incident light level of 1.
If the incident light level of 1 is smaller during long distance
detection, the minimum value by which an output is correctly
turned ON will be set.
Adjust for Moving Workpiece without Stopping Line
Full Auto Tuning
1.
Hold the
button without the presence of a workpiece, and pass the workpiece
through while [
] -> [
+ : Press both
:
Press both in
sequence
(Keep holding the
Power Tuning
seconds or longer until [
When Light
Level is
Saturated
MODE
through, release your finger from the
Setting Reset
L/D
Key Lock
UP/DOWN
MODE
Zero Reset
UP
Refer to "
Convenient
Setting Features".
Workpiece
Mode Change
Output Switch
[MODE]Button
[L/D] Button
A single press switches between
Switches between SET
Light ON/Dark ON. [L/D] Indicator
mode and RUN mode by
a long press (3 seconds
changes.
or longer) of the key.
Incident light level setting: Adjust the max. incident light level on Step 1 as the power tuning level.
Threshold setting: Set to the middle between max. and min. incident light levels on Step 1.
Determine Workpiece Position
Position Tuning
1.
Workpiece
Press
button without a workpiece in the area.
Workpiece
2.
Place the workpiece at the desired position and hold
Incident light level setting: The Step 2 incident level is adjusted to half the power tuning level.
Threshold setting: Set to the same value as the Step 2 incident level.
Detect Transparent or Small Workpiece
1pnt
Percentage Tuning
1.
Turn ON Percentage Tuning in SET mode.
2.
Press
button without a workpiece in the area.
2pnt
Setting is Completed
Incident light level setting: The Step 2 incident light level is adjusted to the
power tuning level.
Threshold setting: Set to the value obtained by [Incident Level at Step 2 x
Percentage Tuning Level + Incident Level at Step 2].
No Smart Tuning other than Power Tuning can be used if Percentage Tuning is set.
Smart Tuning Error
Error / Display / Cause
Near Error
err
The light level difference
between Points 1 and 2 are
extremely small.
Over Error
err
Incident light level is too
high.
Low Error
err
Hold for 3 seconds or longer
Incident light level is too low.
The adjustment range of smart tuning is approx. 20 to 1/100 times. When selecting Giga Mode as
.
detection function, the range will be approx. 2 to 1/100 times due to the large initial value.
Refer to "
Detailed Settings" to change the powr tuning level.
2-4
Minute Adjustment of Threshold Level
1.
Setting is Completed
Press
button to adjust the threshold level.
UP/DOWN
The threshold level becomes higher.
Hold the key for high-speed level adjustment.
-2-
] -> [
] is displayed in red digital.
button while the workpiece passes through, and hold 7
] is displayed in red digital. After the workpiece passes
button.)
Hold for 7 seconds or longer
Setting is Completed
1pnt
button.
Hold for 3 seconds or longer
The red digital display changes
.
Setting is Completed
(Set Threshold by incident light level percentage)
Refer to "
Detailed Settings".
per
Setting is Completed
Error Origin Tuning Type
Remedy
2-point Tuning
• Change the detection function mode to a slower
Full Auto Tuning
response time mode.
Positioning Tuning
• Narrow the emitter and receiver distance (Through-beam)
• Mount the sensor closer to the workpiece (Re ective)
• Enhance the power tuning level.
All
• Use a thin-diameter ber.
• Widen the emitter and receiver distance (Through-beam)
• Distance the sensor from the workpiece (Re ective)
Tuning other than
• Decrease the power tuning level.
Maximum Sensitivity
• Narrow the emitter and receiver distance (Through-beam)
Tuning
• Locate the sensor closer to the workpiece (Re ective)
The threshold level becomes lower.