Set Element Base; Set Serial Number; Set Default - HPE Compaq StorageWorks SSL2000 Series Maintenance And Service Manual

Library
Table of Contents

Advertisement

C-44 Compaq StorageWorks SSL2000 Series Library Maintenance and Service Guide

Set Element Base

Transport: Lets you set the base address of the robotics mechanism. The default is 0000.
Transport:
Transport:
Transport:
Storage: Lets you set the base address of the 19 magazine slots. The default is 0001.
Storage:
Storage:
Storage:
Transfer: Lets you set the base address of the drive. The default is 00E0 for Drive 0.
Transfer:
Transfer:
Transfer:
Import/Export: Lets you set the base address of the mail slot. The default is 00D0.
Import/Export
Import/Export
Import/Export

Set Serial Number

Serial Number: Lets you alter the unit's serial number as stored in the unit. The Library's
Serial Number:
Serial Number:
Serial Number:
robotics reports these settings in response to the SCSI INQUIRY command in the Unit Serial
Number Page.

Set Default

Compaq Defaults: Resets all configuration options to Compaq defaults.
Compaq Defaults:
Compaq Defaults:
Compaq Defaults: