Figure 5-44. Securing The Ptm To The Master Unit - HPE Compaq StorageWorks SSL2000 Series Maintenance And Service Manual

Library
Table of Contents

Advertisement

5-38 Compaq StorageWorks SSL2000 Series Library Maintenance and Service Guide
2. Attach the PTM to the master (top) unit using two bullet-nose thumbscrews and washers
through the top two holes in the extrusion (see Figure 5-44). Do not fully tighten the
thumbscrews at this time.
Thumbscrews
and Washers

Figure 5-44. Securing the PTM to the master unit

3. Align the two holes on the extrusion with mounting holes on the slave unit and attach the
PTM in place using two bullet-nose thumbscrews and washers (Figure 5-42). Do not fully
tighten the thumbscrews at this time.
NOTE: If a screw hole is offset, push the slave unit slightly forward to make a gap between it and the
channel.
4. Repeat Steps 2 through 4 for each additional slave unit. Do not fully tighten the
thumbscrews at this time.
5. Tighten all rear storage cabinet slide screws.
6. Tighten all PTM thumbscrews.
7. Tighten all screws that secure the Library unit's mounting ears to the front of the storage
cabinet.
8. Attach all power and communication cables.