Configuring a Library System
All Libraries are factory-shipped as stand-alone units. To include them in a multi-unit Library
system, you must first configure one unit as the master and all other units as slaves. Any Library
can be configured to be a standalone, master, or slave.
The Master Unit
The master unit controls the operations of a multi-unit Library system. All configuration
changes to the system are performed at the operator panel of the master unit.
NOTE: In a storage cabinet, the master unit must occupy the top position to coordinate the action of the
Pass-Through Mechanism (PTM).
To configure the master unit:
1. From the Default screen, press Enter
u Load/Unload
Remove Magazine
Maintenance Menu
Configure Menu
2. Press the q button three times to move the u to the Configure menu, then press the Enter
button. The following Configure submenu appears. The ¤ at the end of the fourth line
means you can scroll to additional configuration options using the q button.
u SCSI Options
Library Options
Barcode Options
Set Element Base
3. Press the q button to move the u to Library Options, then press the Enter
following screen appears:
u Configuration
*Standalone
Unload Mode
*Implicit
4. Press Enter
Enter to move the cursor to the second line.
Enter
Enter
5. Use the q and p buttons to change the option to Master.
6. Press Enter
Enter to save the selection.
Enter
Enter
NOTE: The change will not take effect until you reboot.
Enter to display the main menu.
Enter
Enter
¤
¤
¤
Installation C-37
Enter
Enter
Enter
Enter button. The
Enter
Enter