Command ===>
Enter or change the Service Coefficients:
CPU
. . . . . . . . . . . . . 1.0
IOC
. . . . . . . . . . . . . 0.1
MSO
. . . . . . . . . . . . . 0.0000
SRB
. . . . . . . . . . . . . 1.0
Enter or change the service definition options:
I/O priority management
Dynamic alias management . . . . . . . . YES
5. (If you want to set the WLM to goal mode) In the WLM View Device Parameter / Feature Definition
screen, verify that DYNAMIC and WLMPAV are set to Yes.
Enabling the Super PAV mainframe system function
By default the Super PAV mainframe system function is disabled on the storage system. If you plan to use
®
the IBM
SuperPAV host function, you must enable the Super PAV mainframe system function on the
storage system in advance.
CAUTION: If the storage system restarts with volatilization (Forced outage with volatile DKC and
DKU, PS-OFF to volatile PS-ON, or Offline microcode replacement), the Super PAV mainframe
system function is reset to the default setting of disabled. If this function was enabled before the
volatilization, you must re-enable it after the volatilization.
Prerequisites
The Storage Administrator (Initial Configuration) role is required to perform this task.
Procedure
1. Click Actions > Mainframe Connection > Edit Mainframe System Functions.
2. Select the Super PAV mainframe system function, click Enable , and then click Finish.
3. In the Task Name text box, accept the default task name ("date-window name"), or type a unique
name for the task.
You can enter up to 32 ASCII characters and symbols, with the exception of the following: \ / : , ; * ? " <
> |.
4. If you want the Tasks window to open after you click Apply, select Go to tasks window for status.
5. Click Apply.
If Go to tasks window for status was selected, the Tasks window opens.
Hyper Parallel Access Volumes enablement from z/OS on
z/VM workflow
Complete the following process to enable HPAV on z/OS and z/VM guest:
Service Coefficient/Service Definition Options
. . . . . . . . YES
(0.0-99.9)
(0.0-99.9)
(0.0000-99.9999)
(0.0-99.9)
(Yes or No)
(Yes or No)
Enabling the Super PAV mainframe system function
37