COMMAND CODE TITLE:
EA
NOTE 6 :
About long call duration of trunk call (fault kind: 04A)
• When Long call duration failure occurs, "Failure occurred" is displayed on the PCPro.
• After a trunk is seized, when the trunk is seized longer time than the monitoring time (1-
60 hours) set by CM42>182, the call is registered as long call duration failure. However,
there is a tolerance up to 30 minutes between monitoring time set by office data and actual
time to be registered.
NOTE 7 :
This data is effective only for PZ-64IPLC-A/PZ-128IPLC-A.
NOTE 8 :
When SRAM memory is unsettled at the time that the system is started up, this fault infor-
mation can be output. (The SMDR data in SRAM memory cannot be guaranteed to save
when the system is power-off for over a week, because the battery of SRAM runs down about
a week later.)
NOTE 9 :
Failure cannot be judged correctly when SRAM data all clear by CM00>02 is never execut-
ed.
NOTE 10:
Fault kind No. 11E is registered when restricted remote access from unassigned Calling
party No. while setting remote maintenance restriction by Calling party No., or restricted
remote access while setting remote maintenance restriction by user operation.
(related command: CMEC Y=B, CM35 Y=319, CM40 Y=10>2, CM41 Y=0>165, CM90
Y=00: F1364)
NOTE 11:
When the restoration kind No. 032 is applied to IPT (P2P CCIS), the restoration message
means "IPT link connection returned to normal condition".
NOTE 12:
The External Alarm Kind for "Number of lockout stations was less than predetermined num-
ber" is fixed to No Alarm. In the case of this office data, even if the 2nd data is set to 0/1/2/
3, it simply means that the fault information is to be registered into Fault Memory. In this
case, External Alarm Kind cannot be changed.
NOTE 13:
Set the output port for fault logs/call logs by CM40 Y=00.
NOTE 14:
When reading this data, second data 1 is displayed normally.