COMMAND CODE TITLE:
31
Y
DATA
A
35
Forward signal receiver minimum Detect
Level
(for Detect Level 0/1/2/3/4/5/6)
[8300R3.5]
NOTE:
36
Forward signal receiver maximum Detect
Level
(for Detect Level 0/1/2/3/4/5/6)
[8300R3.5]
NOTE:
MFC/MF-ANI TRUNK DATA
1ST DATA
MEANING
A reset by CM31 Y=A>90: 0 is required after this data setting.
A reset by CM31 Y=A>90: 0 is required after this data setting.
DATA
00
-10/-15/-20/-25/-30/-35/-40 dBm
01
-11/-16/-21/-26/-31/-36/-41 dBm
02
-12/-17/-22/-27/-32/-37/-42 dBm
03
-13/-18/-23/-28/-33/-38/-43 dBm
04
-14/-19/-24/-29/-34/-39/-44 dBm
05
-15/-20/-25/-30/-35/-40/-45 dBm
06
-16/-21/-26/-31/-36/-41/-46 dBm
07
-17/-22/-27/-32/-37/-42/-47 dBm
08
-18/-23/-28/-33/-38/-43/-48 dBm
09
-19/-24/-29/-34/-39/-44/-49 dBm
10
-20/-25/-30/-35/-40/-45/-50 dBm
11
-21/-26/-31/-36/-41/-46/-51 dBm
12
-22/-27/-32/-37/-42/-47/-52 dBm
13
-23/-28/-33/-38/-43/-48/-53 dBm
14
-24/-29/-34/-39/-44/-49/-54 dBm
15
-25/-30/-35/-40/-45/-50/-55 dBm
NONE
-25/-30/-35/-40/-45/-50/-55 dBm
00
0/-5/-10/-15/-20/-25/-30 dBm
01
-1/-6/-11/-16/-21/-26/-31 dBm
02
-2/-7/-12/-17/-22/-27/-32 dBm
03
-3/-8/-13/-18/-23/-28/-33 dBm
04
-4/-9/-14/-19/-24/-29/-34 dBm
05
-5/-10/-15/-20/-25/-30/-35 dBm
06
-6/-11/-16/-21/-26/-31/-36 dBm
07
-7/-12/-17/-22/-27/-32/-37 dBm
08
-8/-13/-18/-23/-28/-33/-38 dBm
09
-9/-14/-19/-24/-29/-34/-39 dBm
10
-10/-15/-20/-25/-30/-35/-40 dBm
-11/-16/-21/-26/-31/-36/-41 dBm
11
12
-12/-17/-22/-27/-32/-37/-42 dBm
13
-13/-18/-23/-28/-33/-38/-43 dBm
14
-14/-19/-24/-29/-34/-39/-44 dBm
15
-15/-20/-25/-30/-35/-40/-45 dBm
NONE
0/-5/-10/-15/-20/-25/-30 dBm
3-276