[Cm61] External Key Function - NEC UNIVERGE SV8300 Command Manual

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
61
FUNCTION:
This command is used to activate and specify the function of the switch closure detection PGD(2)-U10
ADP when interfaced with external keys.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
ST
+
61YY
+ DE
DATA TABLE:
Y
No.
MEANING
00
Destination of Tenant
01
Change Day/Night trunk
restriction class by external
key
03
Outgoing call restriction
on Night Mode by external
key
05
Day/Night Mode change
by external key
06
Even if station-to-station
call is restricted, calling
tenant is allowed to cancel
restriction by external key
EXTERNAL KEY FUNCTION
KEY NUMBER
+
+
(3 digits)
KEY NUMBER
No.
MEANING
XX Z
XX: Key Group No.
(00-63) assigned by
CM12 Y=66
Z : Circuit No. (0/1)
DATA
DE
+
+
EXE
(1-2 digits)
DATA
00
63
NONE
0
1
0
1
0
1
0
1
3-440
SETTING DATA
MEANING
Tenant 00
Tenant 63
No data
Effective
Ineffective
Effective
Ineffective
Effective
Ineffective
Effective
Ineffective
Continued on next page
NWA-033623-001 Rev.8.1
CM61
: Default
RELATED
COMMAND
CM12 Y=01
CM30 Y=08
CM30 Y=02,
03, 04, 05,
13, 14, 26
CM76 Y=01,
02
CM58
Y=02>09
CM63 Y=1