NEC UNIVERGE SV8300 Command Manual page 232

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
12
Y
No.
MEANING
90
Registered IP Station MAC
Address display/clear
NOTE 1:
If you clear the registered IP Station MAC Address while the system is operating, IP Station is reset
even if it is connected.
NOTE 2:
MAC Address automatic registration in Fixed Connection Mode should be executed during the terminal
logging in.
NOTE 3:
A maximum of 256 MAC Addresses can be registered in Fixed Connection Mode.
NOTE 4:
This command has to be registered after assigning CM15 Y=480 2nd data "1" and CM2B Y=00 in
Fixed Connection Mode. If you do not do that, "DATA ERROR" is displayed.
NOTE 5:
Execute the system data backup by CMEC Y=6>0: 0 after this command registered. When changing
this data of terminals accommodated in a Remote Unit, execute the system data copy by CMEC Y=8 to
the Remote Unit.
NOTE 6:
Confirm the registered MAC Addresses by CM12 Y=92.
92
MAC Address registration
in Fixed Connection Mode
NOTE 1:
A maximum of 256 MAC Addresses can be registered in Fixed Connection Mode.
NOTE 2:
This command has to be registered after assigning CM15 Y=480 2nd data "1" and CM2B Y=00 in
Fixed Connection Mode. If you do not do that, "DATA ERROR" is displayed.
NOTE 3:
When a MAC Address is entered during the terminal logging in incorrectly, "DATA ERROR" is dis-
played. When a MAC Address of the other terminals which is logging in is entered, "WAIT, BUSY
NOW" is displayed.
NOTE 4:
Execute the system data backup by CMEC Y=6>0: 0 after this command is registered.
When changing this data of terminals accommodated in a Remote Unit, execute the system data copy
by CMEC Y=8 to the Remote Unit.
93
Protection Mode Cancel
(forced) for DT700 Series
NOTE:
When entering "CCC", regardless of the result, "OK" is displayed immediately.
STATION CLASS-1
DATA
X.....XXX
MAC Address display
(12 digits)
0
MAC Address automatic registration in Fixed Con-
nection Mode
CCC
Clear
NONE
No data
X.....XXX
MAC Address
(12 digits)
CCC
Clear
NONE
No data
1
Always displayed when the DT700 Series is pro-
tected
CCC
To cancel (forced)
SETTING DATA
MEANING
3-176
CM12
: Default
RELATED
COMMAND
Continued on next page
NWA-033623-001 Rev.8.1
91ch3002.fm
JANUARY/31/2012

Advertisement

Table of Contents
loading