[Cmbc] Presence Service, Sip Converter, Greeting Process Of; Sp350 - NEC UNIVERGE SV8300 Command Manual

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
BC
FUNCTION:
This command is used to assign the data to control Presence Service, SIP Converter or greeting process
of SP350.
[8300R3.5]
ASSIGNMENT PROCEDURE:
ST + BCYY
+ DE
DATA TABLE:
Y
No.
MEANING
03
IP address for Pres-
ence Server
[8300R4]
NOTE:
When Presence Service of SP350 is executed, reset the system after setting this data.
05
Whether the authenti-
cation for each call is
allowed
NOTE 1:
For normal operation, be sure to set the second data to "1" (Allowed) to restrict the unauthorized
connection.
NOTE 2:
The authentication for each call is not provided when the digest authentication is restricted by
CM1D Y=32.
PRESENCE SERVICE, SIP CONVERTER, GREETING PROCESS OF

SP350

1ST DATA
+
+
DE
(3/4 digits)
1ST DATA
DATA
MEANING
001
Fixed value
RESET
1XX
SIP Converter
Group ID
XX: 01 (Unit No.)
2ND DATA
+
+
EXE
(1-15 digits)
DATA
XXX.X
X...X
NONE
0
1
[8300R6
software
or before]
: 01-50
(Unit No.)
[8300R7
software
or later]
3-639
2ND DATA
MEANING
IP address for Pres-
ence Server (Maxi-
mum 15 digits)
XXX.XXX.XXX.XX
X=0.0.0.1-
255.255.255.254
No data
Restricted
CM1D Y=32
Allowed
Continued on next page
NWA-033623-001 Rev.8.1
CMBC
: Default
RELATED
COMMAND
91ch3007.fm