NEC UNIVERGE SV8300 Command Manual page 441

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
44
DATA 1
DATA
MEANING
00
External Hold Tone Machine Start
(PGD(2)-U10 ADP)
[8300R3]
01
External Announcement Machine
Start
[8300R3]
02
Speaker Paging Machine Start
11
Indication for Trunk All Busy
13
TAS Indication
14
Indication for ACD/UCD Call Wait-
ing
15
Relay Control Function Key
35
No. 7 CCIS Link Alarm Display
36
No. 7 CCIS Day/Night Status Dis-
play when the Day/Night Mode is
changed by the main office
38
Fault display for external
[8300R3]
EXTERNAL RELAY STARTING CONDITIONS
DATA
XX
DATA 2
MEANING
00
External Hold Tone for Music on
Hold
09
00
External Announcement Machine
for wake up calling/Timed Reminder
Calling
00
Speaker Paging Zone 0
09
Speaker Paging Zone 9
01
Trunk Group 01
62
Trunk Group 62
00
TAS Group 00
63
TAS Group 63
ACD/UCD Group 00-15
[8300R5 or before]
ACD/UCD Group 00-99
[8300R6 or later]
00
Relay Control (ON/OFF) via Multi-
line Terminal
00
CCH No. 0-15
15
01
Tenant No.
NOTE:
An intra-office Attendant
Console should not be as-
signed for the tenant.
00
MJ Alarms
01
MN Alarms
3-385
CM44
REMARKS
CM48 Y=0
CM48 Y=1
CM12 Y=68
CM20
CM30 Y=09
CM30 Y=13, 14
CM17
CM90 Y=00:
F7XXX
CM08>912
Continued on next page
NWA-033623-001 Rev.8.1
91ch3004.fm
JULY/15/2011

Advertisement

Table of Contents
loading

Table of Contents