Cards And Internal Cables Of The Panel - Honeywell Vigilon 4 loop Generic Commissioning Instructions

Fire panels & network nodes
Table of Contents

Advertisement

Commissioning instructions

Cards and internal cables of the panel

KEYBOARD INDICATORS AND DISPLAY
WARNING
REMOVAL OF COVER
EXPOSES HIGH VOLTAGE
Loop Card 2
Audio Control Card
Controls and indicators
Battery
The lithium battery
connector. The insulation disk must be removed before powering up the system.
BATT3
Remove Sleeve
Setting the Rotary switch SW2
This switch is set to the required position for the panel build on leaving the factory. Before installing the Loop and Network cards into
j
the MCB ensure the rotary switch
SW2 is set to an appropriate setting if it is used as a replacement in an existing panel.
Firmware in socket IC3 of MCB
2211-148
2211-146
2211-136
2211-127
46
Master Control
Board (MCB)
24V
0V
B
A
TX1 RX1 0V
TX2 RX2
L1 0V L2 0V
NC C NO NC C NO NC C NO
L1 0V L2 0V
0V MIPNC C NO
PB15
PB6
PB14
PB10
PB11
PB7
PB9
24V
MA1 - FS1 250mA
FS3 200mA
MA2 - FS2 250mA
P1
CARD 2
P2
CARD 1
FIRMWARE BACKUP
IC3
IC16
0V
L2-
L2+
0V
L1-
L1+
PP2
PB1A
PB1B
SW2
MODE
P2
P16
SW1
RESET
Network Card
Remove
insulation disk
P13
Loop Card 1
NVM Protect - [Disabled]
P13
NVM Protect - [Enabled]
s
is disconnected on leaving the factory by means of an insulation disk over the top
Applicable setting of switch SW2 on MCB
0
1
2
3
Audio Control Card (ACC)
MA1+ MA1- MA2+ MA2-
Power Supply Unit
BGM
AUDIO
AUDIO
L
R
PA MIC 1
PA MIC2
LOOP 1
LOOP 2
24V
B
A
PTT 0V
0V
PA2 PTT2
0V
O/A O/B I/A I/B
O/A O/B I/A I/B
(PSU)
PB8
P15
P14
P10
P12
P13
N E
L
P2
FS3 3.15A(T)
DANGER
Mains fuse
N
L
FS2
FS1
AUDIO LOOP 1
BGM MPG MIC PA
AUDIO LOOP 2
LD1
Warning
Removal of
P1 -
cover exposes
POWER
SMT
P2
-SMT
live parts
P3
DANGER
P9
SUPPLY
P12
P4
AUDIO 1
P2
P1
BATT3
P3
MICROPHONE
P4
P7
P11
BAT1
AUDIO 2
FS4
24V
- 1A TE5
FS6
43V
1A TE5
FS1
Bat 1
- 3.15A TE5
SW2
MODE
SW1
RESET
NVM hardware link P13
The NVM can be enabled or disabled by setting the hardware link
k
P13
on the MCB. If the NVM protect is hardware disabled
then it is possible to software enable or disable the NVM using
the [Protect] option under the [Setup] menu at the panel.
Unprotect: Normally during commissioning the NVM is disabled
(unprotected) and writing to NVM is allowed.
Protect: Once the configuration is backed up to the NVM, the
hardware link must be placed in the enabled position to disallow
writing to the NVM.
Installing the Cards
The MCB can accommodate two Loop Cards. One Loop card
can be fitted into the slot labelled CARD1 and the other Loop
n
card
into the slot labelled CARD2.
"
A networkable system has a Network Card
fitted into the slot CARD 2 on MCB and additionally the
Network Card can accommodate the second Loop card.
Earth Link lead
o
An earth link lead
is supplied with the Network Card. This link
must be fitted to the spade connector on the top edge of MCB
with the other end to the spade connector on the Network Card.
Terminals
p
The terminal blocks
on the top edge of the MCB are used for
wiring external fire system circuits. The terminal block
top edge of the PSU is used for wiring the mains supply to the
r
panel. The connector
located on the bottom edge of the PSU
board is used to accept battery cable. The terminals on the top
edge of the ACC
are used to connect to the audio circuits.
4188-856_issue 7_07/15_Generic Vigilon (Compact + VA) Comms.
l
m
q
on the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vigilon 6 loopVigilon compactVigilon compact va

Table of Contents