2.3.3 Installing EtherNet/IP Master Board Manufactured by molex

Appearance
Part names and functions of the EtherNet/IP Master Board manufactured by molex are
shown in the following figure. For details on the status display LEDs, refer to 4.
Troubleshooting in this manual.
PCU-ETHIO
(Do not use this port.)
Specifications
Part Number
Mode
Baud Rates
Interface
Maximum Node
Connection Type
Explicit message
connection
EDS support
Max. Input Data Size
Max. Output Data Size
Automatic Detection
RC700 / RC90 Option Fieldbus I/O Rev.14
4-pin Terminal
Watchdog Port
LED (2)
(Not in use)
D-Sub 9 pin
(Not in use)
Status Display LED (2)
EtherNetI/P Connector
Item
Jumper Pin for Board Address
Specification
EtherNet/IPMaster Board manufactured by molex
Master
10, 100 (Mbps)
EtherNet/IP 1 port
127
Cyclic, Change of State
Yes
Yes
1024 bit (128 bytes)
1024 bit (128 bytes)
Yes. Devices can be detected automatically.
2. Installation
JP1
JP1
0
1
C0 C1 C2
129