2.5.2 Installing PROFINET Slave Module

■ Make sure that the power is turned OFF before installing/removing any modules
or connecting/disconnecting any cables. Working with the power ON is
extremely hazardous and may result in electrical shock and/or malfunction of
WARNING
equipment.
■ Pay attention to the followings in order to prevent the the connecter from coming
off.
4. Use the connectors attached to the module.
5. Insert the connectors all the way seated.
CAUTION
6. Fix the cables at proper positions in order not to put a load on the
Appearance
Specifications
Name
Connection Method
Protocol
Device type
Baud Rates (bps)
Maximum segment length 100 m
Cable
Cycle time
Interface
Input Data Size
Output Data Size
RC700 / RC90 Option Fieldbus I/O Rev.14
connectors.
LINK/Activity LED
(port 1)
(port 2)
NS LED
Item
MS LED
Specification
PROFINET Slave Module
RT (Real-Time)
PROFINET IO
IO device
100 M bps, full duplex
RJ45 with connector 100BASE-TX (Cat5)
2 ms
RJ45 port × 1
Max. 2048 bits (256 bytes)
Max. 2048 bits (256 bytes)