1. Diagnostic of the TCP/IP layer
RC700 / RC90 Option Fieldbus I/O Rev.14
This dialog box displays the status of the TCP/IP layer.
Configuration Type
Address From
IP address
Sub-Network Mask
Gateway IP Address
Primary DNS Address
Secondary DNS Address IP address of the secondary DNS server.
Host Name
Domain Name
4. Troubleshooting (EtherNet/IP)
Mode type selected in the configuration: DHCP,
BOOTP, Static
How the IP address has been obtained: from the server,
flash memory or factory address.
IP address of the applicomIO master on this channel.
Sub-network address of the applicomIO master on this
channel.
Address of the gateway configured on the applicomIO
master on this channel.
IP Address of the primary DNS server.
Host name of the applicomIO master on this channel.
Domain name of the applicomIO master on this
channel.