4. Troubleshooting (PROFIBUS DP)
4.2.3.6 EPSON RC+ Master Configuration
For details of EPSON RC+ master configuration, refer to the section 2.2.3 Installing
PROFIBUS-DP Master Board Manufactured by molex.
The following section describes the procedure for verifying the scanner board condition
with the applicomIO Console application.
Verifying applicomIO Console application condition
The status bar at the bottom of the window shows the applicomIO Console application
status. The status bar varies as shown below:
Character
Background color : The background color indicates the scanner board status.
Background Character
Gray
Magenta
Red
Yellow
Deep green
Green
314
: The address number of the scanner board is indicated with
characters. When the character "F" appears, the flash memory on
the board initialized the scanner board.
For details, refer to the table below.
Black
Access to scanner board was failed.
After that, the status bar will not be renewed
automatically. To renew the status bar, right-click
the status bar and select [Refresh].
Black
The scanner board was initialized with the earlier
version applicomIO Console application.
It is recommended that the scanner board be written
into the flash memory (reinitializing the scanner
board) again with the current version applicomIO
Console application.
Black
The scanner board was not initialized.
Initialize the scanner board to use it.
Black
The scanner board was partially initialized.
This status happens only during network detection
and on-line actions.
White
Although the scanner board was initialized, it is
different with the currently opened configuration.
(Different version, etc.)
It is recommended that the scanner board be written
into the flash memory (reinitializing the scanner
board) again with the current version applicomIO
Console application.
This status happens only during network detection,
on-line actions, and diagnostic.
Black
The scanner board was initialized properly and it is
no different with the currently opened configuration.
This status happens only during network detection,
on-line actions, and diagnostic.
Status