2. Installation
Prepare the cable for PROFIBUS-DP sold in the market as a communication cable.
NOTE
Install terminating resistors at both ends of the network.
A terminating resistor is installed in the PROFIBUS-DP slave board. Turn the terminating
resistor ON or OFF using the terminator switch on the front panel.
Installing Module
 Make sure that the power is turned OFF before installing/removing any modules
or connecting/disconnecting any cables. Working with the power ON is extremely
hazardous and may result in electrical shock and/or malfunction of equipment.
WARNING
Install the module to the dedicated slot on the T/VT series Manipulator.
Reference: Manipulator manual Setup & Operation 17. Fieldbus I/O
Confirmation with EPSON RC+ 7.0
When a PROFIBUS-DP slave module is installed to the T/VT series Manipulator, it is
recognized automatically.
PROFIBUS-DP module using the following procedure.
1.
2.
3.
122
Select [Setup]-[System Configuration] and display the [System Configuration] dialog
box.
(2)
Select [Inputs / Outputs].
Confirm that the following items are displayed in "Fieldbus Slave".
Installed
: Yes
Inputs
: 512-767 (default setting)
Outputs
: 512-767 (default setting)
Confirm whether EPSON RC+ 7.0 has recognized the