Epson RC90 Manual page 216

Robot controller option fieldbus i/o
Hide thumbs Also See for RC90:
Table of Contents

Advertisement

2. Installation
5.
6.
Editing of Input / Output Size
You can change the input/output size of the CC-Link slave board if necessary.
1.
2.
3.
4.
5.
204
Confirm that the following items are displayed.
Fieldbus Type : CC-Link
Input Bytes
: 32 (default setting)
Output Bytes : 32 (default setting)
Click <Close>.
Select [Setup]-[System Configuration] and display the [System Configuration] dialog
box.
Select [Inputs / Outputs]-[Fieldbus Slave]-[General].
Change the settings of [Input Byte] and [Output Byte].
In this example, both of them are changed to "20" Bytes.
Click <Apply>.
Click <Close> and the following dialog box appears.
The Robot Controller automatically starts rebooting.
RC700 / RC90 Option Fieldbus I/O Rev.14