Installing Module
■ Make sure that the power is turned OFF before installing/removing any modules
or connecting/disconnecting any cables. Working with the power ON is
extremely hazardous and may result in electrical shock and/or malfunction of
WARNING
equipment.
Install the module to the dedicated slot on the T/VT series Manipulator.
Reference: Manipulator manual Setup & Operation 17. Fieldbus I/O
Confirmation of EPSON RC+ 7.0
When the CC-Link slave module is installed to the T/VT series Manipulator, it is
recognized automatically. Confirm whether EPSON RC+ 7.0 has recognized the CC-Link
board using the following procedure.
(1) Select [Setup]-[System Configuration] and display the [System Configuration] dialog
(2) Select [Inputs / Outputs].
(3) Confirm that the following items are displayed in "Fieldbus Slave".
(4) Select [Fieldbus Slave]-[General].
(5) Set each item to the specific value to connect the CC-Link network.
(6) Click <Close>.
RC700 / RC90 Option Fieldbus I/O Rev.14
box.
(2)
Installed
: Yes
Inputs
: 512-767 (default setting)
Outputs
: 512-767 (default setting)
(4)
For information about the setting values, contact your network administrator.
2. Installation
(3)
(5)
213