Step 3 Click Linear Scan button to start the linear scan and click the Linear Scan button
again to stop it.
You can click the Restore button to clear the defined left limit and right limit data and
the dome needs to reboot to make settings take effect.

4.2.9 One-Touch Park

For some certain model of the speed dome, it can be configured to start a predefined park
action (scan, preset, patrol and etc.) automatically after a period of inactivity (park time).
Step 1 Click the button PTZ in the lower-right corner of the PTZ Settings interface;
Or press the PTZ button on the front panel or click the PTZ Control icon
quick setting bar to enter the PTZ setting menu in live view mode.
Step 2 Click the One-touch tab to show the one-touch function of the PTZ control.
Step 3 There are 3 one-touch park types selectable. Click the corresponding button to
activate the park action.
Park (Quick Patrol): The dome starts patrol from the predefined preset 1 to preset
32 in order after the park time. The undefined preset will be skipped.
 