2) Edit the Privacy Information in the text filed to hide the input information overlay.
Up to 3 pieces of privacy information can be edited and no more than 32 characters
can be input for each piece of information.
3) Click OK to save the settings.
Step 5 Select the POS protocol to Universal Protocol, EPSON, AVE or NUCLEUS.
 Universal Protocol
Click the Advanced button to expand more settings when selecting the universal
protocol. You can set the start line tag, line break tag and end line tag for the POS
overlay characters, and the case-sensitive property of the characters.
 NUCLEUS
If you select NUCLEUS protocol, reboot the device to take the new settings into effect.
1) Click Set button to enter the NUCLEUS Settings interface.
2) Edit the Employee, Shift and Terminal information. No more than 32 characters can
be input.
3) Click OK to save the settings.
Note:
 If you select NUCLEUS protocol, the connection type defaults to be RS-232, and all
the other POS protocol will change to be NUCLEUS.
 You should set Usage to be Transparent Channel for RS-232 settings in Menu >
Configuration > RS-232 first.
Step 6 Select the Connection Type to TCP, UDP, Multicast, RS-232, USB->RS-232 or Sniff,
and click Set to configure the parameters for each connection type.
 TCP Connection
When using TCP connection, the port must be set from 0 to 65535, and the port for
each POS machine must be unique. Input the Allowed Remote IP Address for
connecting the DVR and the POS machine via TCP.
 UDP Connection
 
Universal Protocol Settings
TCP Connection Settings
 
128 