Siemens SINAMICS G120 Operating Instructions Manual page 65

Low voltage converters, chassis and wall/panel mounted devices with cu230p-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Table 4- 17
Frame
size
FSA
FSB
FSC
With shield connection kit: FSA: +84 mm; FSB: +85 mm; FSC: +89 mm
1)
Total depth of the inverter: See below.
3)
Table 4- 18
Frame size
FSA, FSB, FSC
Mounting and operation are permissible without lateral clearance. For tolerance reasons we rec-
1)
ommend a lateral clearance of approx. 1 mm.
Converter with CU230P-2 Control Units
Operating Instructions, 04/2015, FW V4.7 SP3, A5E34257946B AB
Dimensions for PM240-2 in push-through technology
Dimensions (mm)
a
b
c
(width)
(height)
(depth)
1
)
126
238
171
154
345
171
200
411
171
Mounting hardware and clearances to other devices for PM240-2 in push-through tech-
nology
Hardware
M5 screws
Drilling dimensions (mm)
T1
T2
e
2)
118
54
103
118
54
147.5
118
54
123
Tightening torque
(Nm)
3
Installing
4.4 Installing Power Modules
Cabinet cutout
(mm)
d
f
g
106
27
88
134
34.5
116
174
30.5
156
Clearances (mm)
Top
Bottom
Lateral
80
100
h
198
304
365
0
1)
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120cSinamics g120p

Table of Contents