Technical data
10.2 Technical data, Power Modules
10.2.1.3

General data, PM230, IP55

Feature
Line voltage
Output voltage
Input frequency
Output frequency
Power factor λ
Line impedance
Starting current
Pulse frequency (factory
setting)
Electromagnetic compatibil-
ity
Braking methods
Degree of protection
Operating temperature
Storage temperature
Relative humidity
Contamination
Environmental requirements Protected against damaging chemical substances according to environmental class 3C2 to
Shock and vibration
Installation altitude
Rated short-circuit current
382
Version
380°V°...°480°V 3-ph.°AC ±°10%
0 V 3-ph. AC ... input voltage x 0.95 (max.)
50 Hz ... 60 Hz, ± 3 Hz
0 Hz ... 550 Hz, depending on the control mode
0.9
Uk ≤ 1%, no line reactor permitted
Less than the input current
4 kHz
The pulse frequency can be increased in 2 kHz steps up to 16 kHz (up to 8 kHz for 75 kW
and 90 kW). An increase in the pulse frequency results in a lower output current.
Conducted interference: The Power Modules correspond to Categories C1 and C2 of the
second environment according to IEC61800-3.
Radiated interference: The Power Modules comply with Category C2 of the second envi-
ronment according to IEC61800-3.
DC braking
FSA ... FSC IP55 / UL Type 12
FSD ... FSF IP55 / UL Type 12 in preparation
Note: For the end cover plate, you must use the relevant bolting plates for the cable glands
and the corresponding cable glands and seals to achieve the degree of protection UP55 (UL
type 12).
Degree of protection IP54 / UL Type 12 is reached if an IOP is inserted.
for operation with LO base load power
for operation with HO base load power
Derating see Restrictions for special ambient conditions (Page 428)
-40 °C ... +70 °C
< 95% - condensation not permissible
Protected from contact with dangerous parts, dust, spray water and water jets
EN 60721-3-3: 1995
Long-term storage in the transport packaging according to Class 1M2 to EN 60721-3-1:
1997
Transport in the transport packaging according to Class 2M3 to EN 60721-3-2: 1997
Vibration during operation according to Class 3M2 to EN 60721-3-3: 1995
without derating:
up to 1000 m above sea level
with derating:
up to 4000 m above sea level
Derating see Restrictions for special ambient conditions (Page 428)
When fused using a type J or 3NE1 fuse, rated voltage 480 V AC
with the rated current of the specific inverter.
FSA ... FSC: 40 kA
FSD ... FSF: 65 kA
-10 °C ... +40 °C; with derating up to 60° C
-10 °C °... +50 °C; with derating up to 60° C
Converter with CU230P-2 Control Units
Operating Instructions, 04/2015, FW V4.7 SP3, A5E34257946B AB