Refilling The Coolant - MIMAKI JFX200-2513EX Operation Manual

Hide thumbs Also See for JFX200-2513EX:
Table of Contents

Advertisement

Chapter 4 Maintenance
• When handling the anti freezing liquid, be sure to wear the included safety glasses and gloves.
• Prepare a tank with a cap for moving the waste water from the cooling water tank.
• The following error message is displayed when water in the cooling water tank is low. In this case, replace
the water in the same way as shown in Refilling the Coolant.

Refilling the Coolant

If the error suggesting lack of water occurs, refill the coolant. Approximately 500 cc of refill is required to fill
the tank to its capacity.
• If the tank is not refilled with coolant for a week after the error message suggesting the lack of water, the
error display changes to "REFILL WATER". You cannot switch to REMOTE mode while this error is on
display. Refill the coolant immediately.
• A buzzer will continue to sound as long as "REFILL WATER" is displayed.
• If you continue to use the machine in the low water state, the error display will switch to "REFILL WATER"
even for a LED-UV temperature error/warning, and it will not be possible to switch to REMOTE mode.
1
Remove the cover of the left rear surface of Y-bar.
• Remove the screw (1 place) indicated with a circle in the figure and remove the cover.
4-40
<LOCAL>
WATER LACK
<LOCAL>
REFILL WATER
Screw

Advertisement

Table of Contents
loading