Table 151: Slave Transmitter mode
Status
Status of the I
Code
and hardware
(I2CSTAT)
0xA8
Own SLA+R has been
received; ACK has
been returned.
0xB0
Arbitration lost in
SLA+R/W as master;
Own SLA+R has been
received, ACK has
been returned.
0xB8
Data byte in I2DAT
has been transmitted;
ACK has been
received.
0xC0
Data byte in I2DAT
has been transmitted;
NOT ACK has been
received.
0xC8
Last data byte in
I2DAT has been
transmitted (AA = 0);
ACK has been
received.
User manual
2
C-bus
Application software response
To/From I2DAT
Load data byte or
Load data byte
Load data byte or
Load data byte
Load data byte or
Load data byte
No I2DAT action or 0
No I2DAT action or 0
No I2DAT action or 1
No I2DAT action
No I2DAT action or 0
No I2DAT action or 0
No I2DAT action or 1
No I2DAT action
Rev. 01 — 15 August 2005
Next action taken by I
To I2CON
STA STO SI
AA
X
0
0
0
Last data byte will be transmitted and
ACK bit will be received.
X
0
0
1
Data byte will be transmitted; ACK will be
received.
X
0
0
0
Last data byte will be transmitted and
ACK bit will be received.
X
0
0
1
Data byte will be transmitted; ACK bit will
be received.
X
0
0
0
Last data byte will be transmitted and
ACK bit will be received.
X
0
0
1
Data byte will be transmitted; ACK bit will
be received.
0
0
0
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address.
0
0
1
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
I2ADR[0] = logic 1.
0
0
0
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address. A START condition will be
transmitted when the bus becomes free.
1
0
0
1
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
I2ADR[0] = logic 1. A START condition
will be transmitted when the bus becomes
free.
0
0
0
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address.
0
0
1
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
I2ADR[0] = logic 1.
0
0
0
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address. A START condition will be
transmitted when the bus becomes free.
1
0
0
01
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
I2ADR.0 = logic 1. A START condition will
be transmitted when the bus becomes
free.
UM10139
2
Chapter 11: I
C interfaces
2
C hardware
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.