The Operation and Questionable Data Status Register Groups

The Operation and Questionable Data Status Register Groups have the following
registers:
– a condition register
– one or more transition filters
– an event register
– an event enable register
Figure 3-15
Device Status
Continuously
Monitored
Figure 3-15
Keysight 53147A/148A/149A Operating and Programming Guide
shows the model that these register groups follow.
*
= positive transition, or
negative transition, or
either transition.
See Table 3-6.
Condition
Transition
Register
Filter
0
*
1
*
2
*
n-1
*
n
*
Operation and Questionable Data Status Reporting Model
Event
Register
(Logical AND)
0
&
1
&
2
&
n-1
n
Logical OR
Summary Bit
(OSB or QSB)
Status Byte Register
Programming
3
Event
Enable
Register
0
1
2
&
n-1
&
n