Modbus communication
A.9 Modbus holding registers tables
A.9.4.5

Date and time

General settings
Table A- 70
General settings
Modbus
Data type /
register
Size in bytes
6185
Unsigned / 2
6186
Unsigned / 2
6187
Unsigned / 2
6188
Unsigned / 2
6189
Unsigned / 2
6669
Unsigned / 2
6184
Unsigned / 2
270
Parameter
Description
Year
Holds current year
after Get time com-
mand was carried out.
Holds year before Set
time command is car-
ried out.
Month
Holds current month
after Get time com-
mand was carried out.
Holds month before
Set time command is
carried out.
Day
Holds current day after
Get time command
was carried out.
Holds day before Set
time command is car-
ried out.
Hours
Holds current hours
after Get time com-
mand was carried out.
Holds hours before Set
time command is car-
ried out.
Minutes
Holds current minutes
after Get time com-
mand was carried out.
Holds minutes before
Set time command is
carried out.
Seconds
Holds current seconds
after Get time com-
mand was carried out.
Holds seconds before
Set time command is
carried out.
Get time
Command to get the
device's current time
by using the separate
parameters above.
Default value
Value range /
[unit]
Setting options
(unit register)
2016
2001 - 2099
1
1 - 12
1
1 - 31
0
0 - 23
0
0 - 59
0
0 - 59
-
0: Cancel
1: Get time
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Access
level
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write
Write
only