Siemens SITRANS F series Operating Instructions Manual page 204

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F series:
Table of Contents

Advertisement

Modbus communication
A.9 Modbus holding registers tables
Modbus
Data type /
register
Size in bytes
8880
Float / 4
10000
Float / 4
10002
Float / 4
10004
Float / 4
10006
Float / 4
10008
Float / 4
202
Parameter
Description
Lower range
Lower standard volume
value standard
flow value that is
volume flow
mapped to the lower
nominal range bounda-
ry selected by Current
mode (8806). Applica-
ble if Process value
(8802) = 27.
Upper range
Upper velocity value
value velocity
that is mapped to the
upper nominal range
boundary selected by
Current mode (8806).
Applicable if Process
value (8802) = 18, 19
or 31.
Lower range
Lower velocity value
value velocity
that is mapped to the
lower nominal range
boundary selected by
Current mode (8806).
Applicable if Process
value (8802) = 18, 19
or 31.
Upper range
Upper process pres-
value pressure
sure value that is
mapped to the upper
nominal range bounda-
ry selected by Current
mode (8806). Applica-
ble if Process value
(8802) = 20.
Lower range
Lower process pres-
value pressure
sure value that is
mapped to the lower
nominal range bounda-
ry selected by Current
mode (8806). Applica-
ble if Process value
(8802) = 20.
Upper range
Upper dimensionless
value dimen-
value that is mapped to
sionless
the upper nominal
range boundary se-
lected by Current mode
(8806). Applicable if
Process value (8802) =
28, 32, 33, 34, or 36.
Default value
Value range /
[units]
Setting options
(units regis-
ter)
0.0
-
[Sm
/h]
3
(7964)
1.0
-
[m/s]
(8014 / 7648)
0.0
-
[m/s]
(8014 / 7648)
100000.0
-
[Pa]
(7548)
0.0
-
[Pa]
(7548)
1.0
-
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Access
level
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fst030

Table of Contents